Specification: Part Number 1052627 Object remission: 4 % ... > 1,000 % (reflectors) CAN bus: - Light source: Infrared (850 nm) Delay time: 134 ms ... 30,000 ms (programmable) Switching outputs: 3 (PNP, plus 1 x "device ready") Protection class: III (EN 60950-1/A11 (2009-03)) Electrical connection: 1 x 15-pin D-sub HD male connector (0.9 m) Weight: 150 g, without connecting cables Ambient light safety: 15,000 lx Optical indicators: 2 LEDs (ON, switching status) Electromagnetic compatibility (EMC): EN 61000-6-3 (2007-01) / EN 61000-6-2 (2005-08) Detectable object shape: Almost any DeviceNet: - Statistical error : ± 30 mm Field of view: 270 ° Angular resolution: 1 ° Function (USB): AUX, parameterization Ethernet: - Laser class: 1 (EN 60825-1 (2007-10)), eye-safe Storage temperature: -30 °C ... +70 °C Note on use: Not suitable for personnel protection PROFINET: - Housing color: Light blue (RAL 5012) Systematic error : ± 40 mm Enclosure rating: IP 65 (EN 60529/A1:2000-02) Scanning frequency: 15 Hz Operating range: 0.05 m ... 4 m Integrated application: Field evaluation Ambient operating temperature: -10 °C ... +50 °C Response time: Typ. 134 ms Dimensions: 60 mm x 60 mm x 79 mm Vibration resistance: EN 60068-2-6 (2008-02) PROFIBUS DP: - USB: + Number of field sets: 16 field triples (48 fields, 1 triple (3 fields) programmable directly at the scanner) Dwell time: 67 ms ... 10,000 ms (programmable) Serial (RS-232): - Shock resistance: EN 60068-2-27 (2009-05) Operating voltage: 9 V DC ... 28 V DC Switching inputs: 4 (PNP) Simultaneous processing cases: 1 (3 fields) Max. range with 10 % reflectivity: 2 m Power consumption: 3 W Remark (USB): Micro USB