Specification: Part Number 1052077 Protection class: III Process connection: G ¾ A Response time: < 400 ms Lower signal level: 3.8 mA ... 4 mA Power consumption: ≤ 75 mA at 24 V DC without output load Hysteresis: Min. 2 mm, free adjustable Supply voltage: 12 V DC ... 30 V DC MTTF: 194.3 a (EN ISO 13849-1) Ambient storage temperature: -40 °C ... +80 °C IO-Link: + Process temperature: -20 °C ... +150 °C EHEDG approval: + Inactive area at probe end: 10 mm Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Housing design: With PMMA viewing window Inductive load: < 1 H Interference resistance: EN 61000-6-2:2005 Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Connection type: Round connector M12 x 1, 5-pin Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Accuracy of sensor element: ± 5 mm Output current: < 100 mA Upper signal level: 20 mA ... 20.5 mA Conductivity: No limitation Max.probe load: 6 Nm EMC: EN 61326-1:2006, 2004/108/EG Resolution: < 2 mm Measurement: Switch, Continuous Probe length: 1,200 mm Housing material: 303 Capacitive load: 100 nF GOST approval: + Single- and continuous shock: EN 60068-2-27 Ambient temperature operation: -20 °C ... +60 °C Inactive area at process connector: 25 mm Signal voltage LOW: ≤ 2 V Medium: Fluids Temperature drift: < 0.1 mm/K RoHS certificate: + Signal voltage HIGH: Vs - 2 V Initialization time: ≤ 2 s Interference emission: EN 61000-6-4:2007 Process pressure: -1 bar ... 16 bar 3-A: - Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V UL approval: + Repeatability: ≤ 2 mm