Specification: Part Number 1062252 Connection type: Round connector M12 x 1, 8-pin Hysteresis: Min. 2 mm, free adjustable Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Inductive load: < 1 H Accuracy of sensor element: ± 5 mm RoHS certificate: + CULus certificate: + Protection class: III Inactive area at process connector: 25 mm Lower signal level: 3.8 mA ... 4 mA Process pressure: -1 bar ... 10 bar MTTF: 194.3 a (EN ISO 13849-1) Housing material: Plastic PBT Resolution: < 2 mm Max.probe load: 6 Nm Measurement: Switch, Continuous Power consumption: ≤ 100 mA at 24 V DC without output load Supply voltage: 12 V DC ... 30 V DC Conductivity: No limitation Probe length: 900 mm EMC: EN 61326-1:2006, 2004/108/EG Capacitive load: 100 nF Medium: Fluids Inactive area at probe end: 10 mm Enclosure rating: IP 67: EN 60529 Output current: < 100 mA GOST approval: + Probe type: Mono rod probe Process temperature: -20 °C ... +100 °C Design: Standard Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Signal voltage LOW: ≤ 2 V Process connection: G ¾ A Upper signal level: 20 mA ... 20.5 mA Wetted parts: 1.4404, PTFE Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Response time: < 400 ms Initialization time: ≤ 5 s Signal voltage HIGH: Vs - 2 V Ambient storage temperature: -40 °C ... +80 °C Ambient temperature operation: -20 °C ... +60 °C Temperature drift: < 0.1 mm/K Repeatability: ≤ 2 mm IO-Link: + Maximum level change: 500 mm/s