Specification: Part Number 1071141 Interference emission: EN 61000-6-4:2007 Lower signal level: 3.8 mA ... 4 mA Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK IO-Link: + Capacitive load: 100 nF Housing material: 303 Process temperature: -20 °C ... +180 °C Measurement: Switch, Continuous Output current: < 100 mA RoHS certificate: + GOST approval: + EHEDG approval: + Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Ambient temperature operation: -20 °C ... +60 °C Max.probe load: 6 Nm Initialization time: ≤ 2 s UL approval: + Accuracy of sensor element: ± 5 mm Inactive area at probe end: 10 mm Protection class: III Ambient storage temperature: -40 °C ... +80 °C Response time: < 400 ms Process pressure: -1 bar ... 16 bar Inductive load: < 1 H EMC: EN 61326-1:2006, 2004/108/EG Conductivity: No limitation Length coaxial cable: 3.3 m, FEP Repeatability: ≤ 2 mm Interference resistance: EN 61000-6-2:2005 Process connection: ¾" NPT Upper signal level: 20 mA ... 20.5 mA Temperature drift: < 0.1 mm/K Signal voltage LOW: ≤ 2 V Hysteresis: Min. 2 mm, free adjustable Connection type: Round connector M12 x 1, 5-pin Signal voltage HIGH: Vs - 2 V 3-A: - Housing design: With PMMA viewing window Power consumption: ≤ 75 mA at 24 V DC without output load Medium: Fluids MTTF: 194.3 a (EN ISO 13849-1) Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Resolution: < 2 mm Inactive area at process connector: 25 mm Supply voltage: 12 V DC ... 30 V DC Probe length: 700 mm Single- and continuous shock: EN 60068-2-27 Ambient temperature coaxial cable: -20 °C ... +60 °C Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050