Specification: Part Number 1062250 Process connection: G ¾ A Inactive area at process connector: 25 mm Housing material: Plastic PBT Response time: < 400 ms Hysteresis: Min. 2 mm, free adjustable Process pressure: -1 bar ... 10 bar Probe type: Mono rod probe Process temperature: -20 °C ... +100 °C Power consumption: ≤ 100 mA at 24 V DC without output load Inductive load: < 1 H RoHS certificate: + Signal voltage LOW: ≤ 2 V Design: Standard Ambient temperature operation: -20 °C ... +60 °C MTTF: 194.3 a (EN ISO 13849-1) Capacitive load: 100 nF Output signal: 1 PNP transistor output (Q1) und 3 PNP / NPN transistor output (Q2...Q4) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Signal voltage HIGH: Vs - 2 V Protection class: III Inactive area at probe end: 10 mm IO-Link: + Max.probe load: 6 Nm Repeatability: ≤ 2 mm Lower signal level: 3.8 mA ... 4 mA GOST approval: + Temperature drift: < 0.1 mm/K EMC: EN 61326-1:2006, 2004/108/EG Connection type: Round connector M12 x 1, 8-pin Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe CULus certificate: + Output current: < 100 mA Wetted parts: 1.4404, PTFE Accuracy of sensor element: ± 5 mm Medium: Fluids Probe length: 700 mm Supply voltage: 12 V DC ... 30 V DC Measurement: Switch, Continuous Maximum level change: 500 mm/s Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V Initialization time: ≤ 5 s Ambient storage temperature: -40 °C ... +80 °C Enclosure rating: IP 67: EN 60529 Conductivity: No limitation Resolution: < 2 mm Upper signal level: 20 mA ... 20.5 mA