Specification: Part Number 1053288 Supply voltage: 12 V DC ... 30 V DC Measurement: Switch, Continuous Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V EHEDG approval: + GOST approval: + Interference resistance: EN 61000-6-2:2005 Response time: < 400 ms Accuracy of sensor element: ± 5 mm Process pressure: -1 bar ... 16 bar Ambient storage temperature: -40 °C ... +80 °C Inductive load: < 1 H Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Process temperature: -20 °C ... +150 °C Hysteresis: Min. 2 mm, free adjustable Power consumption: ≤ 75 mA at 24 V DC without output load Resolution: < 2 mm Output current: < 100 mA Initialization time: ≤ 2 s Temperature drift: < 0.1 mm/K 3-A: - Probe length: 300 mm IO-Link: + Repeatability: ≤ 2 mm Capacitive load: 100 nF Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK Signal voltage HIGH: Vs - 2 V EMC: EN 61326-1:2006, 2004/108/EG Lower signal level: 3.8 mA ... 4 mA Housing material: 303 Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe UL approval: + Housing design: With PMMA viewing window Conductivity: No limitation Single- and continuous shock: EN 60068-2-27 Ambient temperature operation: -20 °C ... +60 °C Protection class: III Signal voltage LOW: ≤ 2 V MTTF: 194.3 a (EN ISO 13849-1) Inactive area at process connector: 25 mm Interference emission: EN 61000-6-4:2007 Inactive area at probe end: 10 mm Upper signal level: 20 mA ... 20.5 mA Connection type: Round connector M12 x 1, 5-pin Process connection: G ¾ A RoHS certificate: + Medium: Fluids Max.probe load: 6 Nm