Specification: Part Number 1207169 Safe state in the event of a fault: At least one OSSD is in the OFF state. Weight: 420 g Ripple: ≤ 10 % Protection class: III (EN 61140) Ambient operating temperature: -20 °C ... +55 °C Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Synchronization: Optical, without separate synchronization Restart interlock (delivery status): Deactivated Safe SICK device communication via EFI/SDL: - Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Response time: ≤ 13 ms Scanning range: 0 m ... 4 m Housing cross-section (incl. system connection): 15 mm x 32 mm Restart interlock: + Display elements: LEDs Conductor cross-section: 0.34 mm² TM (mission time): 20 a (EN ISO 13849) Air humidity: 15 % ... 95 %, non-condensing Storage temperature: -25 °C ... +70 °C External device monitoring (delivery status): Deactivated Performance level: PL e (EN ISO 13849) External device monitoring (EDM): + Protective field height: 1,200 mm Beam coding: + Type: Type 4 (IEC 61496) Configuration method: Hard wired Permitted cable length: ≤ 20 m Automatic beam coding: + Switching voltage LOW: 2 V DC Cable length: 700 mm Cascaded: - Housing material: Aluminum alloy ALMGSI 0.5 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Typical range: 0 m ... 5 m Connection type: Male connector M12, 5-pin Resolution: 34 mm Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Category: Category 4 (EN ISO 13849) PFHd: Standalone system: 4.3 1E-09 (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Switching current: 300 mA Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Power consumption: ≤ 3 A