Specification: Part Number 1207252 Type: Type 4 (IEC 61496) Restart interlock (delivery status): Deactivated Housing cross-section (incl. system connection): 15 mm x 32 mm Cascaded: - PFHd: Standalone system: 4.3 1E-09 (EN ISO 13849) External device monitoring (delivery status): Deactivated Shock resistance: 10 g, 16 ms (EN 60068-2-27) Beam coding: + Air humidity: 15 % ... 95 %, non-condensing Conductor cross-section: 0.34 mm² Safe state in the event of a fault: At least one OSSD is in the OFF state. Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Switching voltage LOW: 2 V DC Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Synchronization: Optical, without separate synchronization Configuration method: Hard wired Enclosure rating: IP 65 (EN 60529) TM (mission time): 20 a (EN ISO 13849) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Category: Category 4 (EN ISO 13849) External device monitoring (EDM): + Response time: ≤ 13 ms Typical range: 0 m ... 5 m Power consumption: ≤ 3 A Cable length: 700 mm Connection type: Male connector M12, 5-pin Protection class: III (EN 61140) Display elements: LEDs Restart interlock: + Weight: 255 g Storage temperature: -25 °C ... +70 °C Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Switching current: 300 mA Resolution: 34 mm Safe SICK device communication via EFI/SDL: - Automatic beam coding: + Housing material: Aluminum alloy ALMGSI 0.5 Ambient operating temperature: -20 °C ... +55 °C Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Performance level: PL e (EN ISO 13849) Permitted cable length: ≤ 20 m Scanning range: 0 m ... 4 m Protective field height: 720 mm Ripple: ≤ 10 %