Operating temperature -25...+85 °C -40...+85 °C (optional) Weight approx. 400 g Relative humidity 95 % non-condensing Protection DIN EN 60529 IP 54 IP 65 (optional) Incremental output 2048 pulses A90°B + inverted Voltage supply 10...30 VDC Resistance DIN EN 60068-2-6 Vibration 10 g, 16-2000 Hz DIN EN 60068-2-27 Shock 100 g, 6 ms Code sequence CW/CCW coded by connection Starting torque ≤0.015 Nm (IP 54) Function Multiturn Operating speed ≤6000 rpm (mechanical) ≤6000 rpm (electric) Initializing time typ. 20 ms after power on Interfaces SSI Incremental A 90° B (optional) Number of turns 4096 / 12 bit Interference immunity DIN EN 61000-6-2 Absolute accuracy ±0.025 ° Connection Connector M23, 12-pin Consumption w/o load ≤50 mA (24 VDC) Shaft type ø12 mm (blind hollow shaft) ø14 mm (blind hollow shaft) ø15 mm (blind hollow shaft) manufacter SKU GXM2S Emitted interference DIN EN 61000-6-4 Rotor moment of inertia 20 gcm² Inputs SSI clock Control signals UP/ DOWN and zero Code Gray or binary Materials Housing: steel Flange: aluminium Sensing method Optical Starting acceleration ≤1000 U/s² Size (flange) ø58 mm Approval UL approval / E63076 Steps per turn ≤16384 / 14 bit Diagnostic functions Self-diagnosis Multiturn sensing Reverse polarity protection Yes Output stages SSI data: linedriver RS485 Diagnostic and incremental outputs