Specification: Part Number 6038695 Reference conditions: Reference conditions: According to IEC 61298-1 Shock load: 500 g according to IEC 60068-2-27 (mechanical shock) Internal transmission fluid: Silicone oil (only with pressure ranges < 0 bar ... 10 bar and ≤ 0 bar abs ... 25 bar abs) Enclosure rating: IP 67 Ambient temperature: 0 °C ... +80 °C Compound pressure: -1 bar ... 0 bar up to -1 bar ... +24 bar Isolation voltage: 500 V DC Service life: Minimum 100 Mio. life cycles Signal noise: ≤ 0.3 % of span Process connection: G ¼ A according to DIN 3852-E CE-conformity: Pressure equipment directive: 97/23/EC, EMC directive: 2004/108/EC, EN 61 326-2-3 Pressure type: Compound pressure Non-repeatability: ≤ 0.1 % of span Electrical safety: Short-circuit protection: QA towards M, Protection class: III, Overvoltage protection: 32 V DC, 36 V DC with 4 mA ... 20 mA, Reverse polarity protection: L+ towards M Non-linearity: ≤ ± 0.5 % ((Best Fit Straight Line, BFSL) according to IEC 61298-2) Rated temperature range: 0 °C ... +80 °C Wetted parts: Pressure connection: stainless steel 316L, Pressure sensor: stainless steel 316L (for measurement ranges from 0 bar ... 10 bar rel stainless steel 13-8 PH) Connection type: Round connector M12 x 1, 4-pin, IP 67 Process temperature: 0 °C ... +80 °C Gauge pressure: 0 bar ... 1 bar up to bar ... 600 bar Measuring range: -1 bar ... 15 bar Power consumption: Max. 8 mA for voltage output signal, Signal current (max. 25 mA) for current output Storage temperature: -20 °C ... +80 °C Vibration load: 10 g according to IEC 60068-2-6 (vibration under resonance), 20 g optional Adjustment accuracy of zero signal: ≤ 0.5 % of span typ., ≤ 0.8 % of span max. (with non-linerarity 0.5 %) Relative humidity: 45 % ... 75 % Seal: NBR Long-term drift/one-year stability: ≤ 0.1 % of span according to IEC 61298-2 Pressure port: Standard Response time: < 4 ms Hysteresis: ≤ 0.16 % of span Accuracy: ≤ ± 0,6 % of Span (with non-linearity 0.25 % and with signal output 0 ... 5 V), ≤ ± 1 % of span (with non-linearity 0.25 %), ≤ ± 1,0 % of Span (with non-linearity 0.5 %), (Including non-linearity, hysteresis, zero point and full scale error (corresponds to error of measurement according to IEC 61298-2)) Output signal: 4 mA ... 20 mA Weight sensor: Ca. 80 g Absolute pressure: 0 bar ... 1 bar up to 0 bar ... 25 bar Medium: Liquid and gaseous media Protection class III: + Housing material: Stainless steel 316L