Specification: Part Number 1057088 Power consumption: ≤ 100 mA at 24 V DC without output load Inductive load: < 1 H CULus certificate: + Response time: < 400 ms Upper signal level: 20 mA ... 20.5 mA Protection class: III Process temperature: -20 °C ... +100 °C Temperature drift: < 0.1 mm/K Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 350 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 15 V IO-Link: + Process connection: G ¾ A RoHS certificate: + Ambient temperature operation: -20 °C ... +60 °C Housing material: Plastic PBT Measurement: Switch, Continuous Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono rod probe / rope probe Repeatability: ≤ 2 mm Signal voltage HIGH: Vs - 2 V Max.probe load: 6 Nm GOST approval: + Lower signal level: 3.8 mA ... 4 mA Accuracy of sensor element: ± 5 mm Capacitive load: 100 nF Inactive area at probe end: 10 mm Hysteresis: Min. 2 mm, free adjustable Probe type: Mono rod probe Inactive area at process connector: 25 mm Medium: Fluids Maximum level change: 500 mm/s Connection type: Round connector M12 x 1, 5-pin Wetted parts: 1.4404, PTFE Conductivity: No limitation MTTF: 194.3 a (EN ISO 13849-1) Supply voltage: 12 V DC ... 30 V DC Enclosure rating: IP 67: EN 60529 Output signal: 1 PNP transistor output (Q1) and 1 PNP / NPN transistor output (Q2) switchable, 4 mA ... 20 mA, 0 V ... 10 V automatic switching depending on the load. Resolution: < 2 mm Signal voltage LOW: ≤ 2 V Output current: < 100 mA Initialization time: ≤ 5 s Probe length: 1,700 mm Design: Standard EMC: EN 61326-1:2006, 2004/108/EG Ambient storage temperature: -40 °C ... +80 °C Process pressure: -1 bar ... 10 bar