Specification: Part Number 1056296 Resolution: < 2 mm MTTF: 194.3 a (EN ISO 13849-1) RoHS certificate: + Output load: 0 V ... 10 V > 750 Ohm at Uv >= 14 V, 4 mA ... 20 mA < 400 Ohm at Uv > 12 V, 4 mA ... 20 mA < 500 Ohm at Uv > 13,5 V Accuracy of sensor element: ± 5 mm Repeatability: ≤ 2 mm Wetted parts: 316L (Ra ≤ 0,8 µm), PEEK UL approval: + Housing design: With closed cover Capacitive load: 100 nF Ambient storage temperature: -40 °C ... +80 °C Probe length: 1,400 mm Medium: Fluids Hysteresis: Min. 2 mm, free adjustable 3-A: - Process pressure: -1 bar ... 16 bar Interference resistance: EN 61000-6-2:2005 Signal voltage HIGH: Vs - 2 V Initialization time: ≤ 2 s Signal voltage LOW: ≤ 2 V Single- and continuous shock: EN 60068-2-27 IO-Link: + Power consumption: ≤ 75 mA at 24 V DC without output load Inductive load: < 1 H Ambient temperature operation: -20 °C ... +60 °C Housing material: 303 Connection type: Round connector M12 x 1, 5-pin Supply voltage: 12 V DC ... 30 V DC Enclosure rating: IP 67: EN 60529, IP 69K: EN 40050 Process temperature: -20 °C ... +150 °C Interference emission: EN 61000-6-4:2007 Dielectricity constant: ≥ 1.8 with coaxial tube, ≥ 5 for mono probe Protection class: III Measurement: Switch, Continuous GOST approval: + EHEDG approval: + Response time: < 400 ms Output current: < 100 mA Lower signal level: 3.8 mA ... 4 mA Process connection: G ¾ A Inactive area at probe end: 10 mm Inactive area at process connector: 25 mm Max.probe load: 6 Nm EMC: EN 61326-1:2006, 2004/108/EG Temperature drift: < 0.1 mm/K Conductivity: No limitation Upper signal level: 20 mA ... 20.5 mA