Specification: Part Number 1036165 Material: AlMgSiPbF28 Mass: 3.6 kg Storage temperature range: -40 °C ... +85 °C Piston speed: 6.6 m/s Data protocol: Profibus DP basic functions, Profile for encoders (07hex) - Class 2 Enclosure rating: IP 67 (IEC 60529), with mating connector inserted Resistance to shocks: 30 g, 10 ms (DIN EN 60 068-2-27) Connection type: 3 x connector M12 Resistance to vibration: 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) Bus interface: RS-485 Measuring range: 354 m Electrical interface: PROFIBUS DP Measuring length: 0 m ... 354 m Address setting: 0 ... 127, Hex switches or Protocol SET (electronic adjustment): Via protocol Bus termination: Via external switches Resolution: 0.1 mm Repeat accuracy: 0.3 mm EMC: (according to EN 61000-6-2 and EN 61000-6-4) MTTFd: mean time to dangerous failure: 28 a (EN ISO 13849) Supply voltage: 10 V ... 32 V Initialization time: 2 s Measurement accuracy: ± 1000 + ME (Tu-25° C) Tk µm Status information: Operation (LED green), Bus aktivity (LED red) Working temperature range: -20 °C ... +60 °C Position forming time: 1.1 ms Position tolerance: ± 10 mm Power consumption: 2.5 W