Specification: Part Number 1036163 SET (electronic adjustment): Via protocol Resistance to vibration: 10 g, 20 Hz ... 250 Hz (EN 60068-2-6) Measuring range: 38 m Bus termination: Via external switches Working temperature range: -20 °C ... +60 °C Resistance to shocks: 30 g, 10 ms (DIN EN 60 068-2-27) EMC: (according to EN 61000-6-2 and EN 61000-6-4) Power consumption: 2.5 W Position forming time: 1.1 ms MTTFd: mean time to dangerous failure: 40 a (EN ISO 13849) Mass: 2.4 kg Status information: Operation (LED green), Bus aktivity (LED red) Supply voltage: 10 V ... 32 V Measuring length: 0 m ... 38 m Data protocol: Profibus DP basic functions, Profile for encoders (07hex) - Class 2 Address setting: 0 ... 127, Hex switches or Protocol Piston speed: 6.6 m/s Connection type: 3 x connector M12 Enclosure rating: IP 67 (IEC 60529), with mating connector inserted Initialization time: 2 s Bus interface: RS-485 Repeat accuracy: 0.3 mm Material: AlMgSiPbF28 Measurement accuracy: ± 1000 + ME (Tu-25° C) Tk µm Position tolerance: ± 10 mm Storage temperature range: -40 °C ... +85 °C Resolution: 0.1 mm Electrical interface: PROFIBUS DP