Specification: Part Number 1207314 Enclosure rating: IP 65 (EN 60529) Cascaded: + Synchronization: Optical, without separate synchronization Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Category: Category 4 (EN ISO 13849) Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Beam coding: + Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Housing material: Aluminum alloy ALMGSI 0.5 Scanning range: 0 m ... 4 m Restart interlock: + Restart interlock (delivery status): Deactivated Safe SICK device communication via EFI/SDL: - Resolution: 34 mm Typical range: 0 m ... 5 m Protection class: III (EN 61140) Power consumption: ≤ 3 A External device monitoring (EDM): + Ambient operating temperature: -20 °C ... +55 °C PFHd: Cascaded systems: 1.3 1E-08 (EN ISO 13849) Safe state in the event of a fault: At least one OSSD is in the OFF state. Cable length: 700 mm Switching voltage LOW: 2 V DC Configuration method: Hard wired Ripple: ≤ 10 % Permitted cable length: ≤ 20 m External device monitoring (delivery status): Deactivated Storage temperature: -25 °C ... +70 °C Weight: 340 g Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Type: Type 4 (IEC 61496) Response time: ≤ 13 ms Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Conductor cross-section: 0.34 mm² TM (mission time): 20 a (EN ISO 13849) Housing cross-section (incl. system connection): 15 mm x 32 mm Connection type: Male connector M12, 5-pin Display elements: LEDs Automatic beam coding: + Switching current: 300 mA Connection type extension connection: Female connector M12, 5-pin Shock resistance: 10 g, 16 ms (EN 60068-2-27) Air humidity: 15 % ... 95 %, non-condensing Protective field height: 960 mm Performance level: PL e (EN ISO 13849)