Specification: Part Number 1207309 Beam coding: + Safe state in the event of a fault: At least one OSSD is in the OFF state. Shock resistance: 10 g, 16 ms (EN 60068-2-27) Conductor cross-section: 0.34 mm² Connection type extension connection: Female connector M12, 5-pin Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Category: Category 4 (EN ISO 13849) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Restart interlock (delivery status): Deactivated External device monitoring (delivery status): Deactivated Switching current: 300 mA TM (mission time): 20 a (EN ISO 13849) Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Protective field height: 660 mm Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Permitted cable length: ≤ 20 m Performance level: PL e (EN ISO 13849) Synchronization: Optical, without separate synchronization Ambient operating temperature: -20 °C ... +55 °C Typical range: 0 m ... 5 m Configuration method: Hard wired Type: Type 4 (IEC 61496) Safe SICK device communication via EFI/SDL: - Enclosure rating: IP 65 (EN 60529) Cascaded: + Weight: 235 g Protection class: III (EN 61140) Ripple: ≤ 10 % Response time: ≤ 13 ms Cable length: 700 mm Storage temperature: -25 °C ... +70 °C Connection type: Male connector M12, 5-pin Housing material: Aluminum alloy ALMGSI 0.5 Resolution: 34 mm Restart interlock: + Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Automatic beam coding: + Power consumption: ≤ 3 A Scanning range: 0 m ... 4 m Display elements: LEDs PFHd: Cascaded systems: 1.3 1E-08 (EN ISO 13849) Air humidity: 15 % ... 95 %, non-condensing Switching voltage LOW: 2 V DC External device monitoring (EDM): + Housing cross-section (incl. system connection): 15 mm x 32 mm