Specification: Part Number 1207122 Beam coding: + Protection class: III (EN 61140) Category: Category 4 (EN ISO 13849) Housing material: Aluminum alloy ALMGSI 0.5 Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Storage temperature: -25 °C ... +70 °C Shock resistance: 10 g, 16 ms (EN 60068-2-27) Cascaded: + Resolution: 14 mm Restart interlock: + Scanning range: 0 m ... 4 m Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Connection type extension connection: Female connector M12, 5-pin Configuration method: Hard wired Response time: ≤ 14 ms External device monitoring (EDM): + Protective field height: 540 mm Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Restart interlock (delivery status): Deactivated TM (mission time): 20 a (EN ISO 13849) Enclosure rating: IP 65 (EN 60529) Safe state in the event of a fault: At least one OSSD is in the OFF state. Performance level: PL e (EN ISO 13849) Cable length: 350 mm Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Housing cross-section (incl. system connection): 15 mm x 32 mm Ambient operating temperature: -20 °C ... +55 °C Switching current: 300 mA Safe SICK device communication via EFI/SDL: - Conductor cross-section: 0.34 mm² Power consumption: ≤ 3 A Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) External device monitoring (delivery status): Deactivated Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Automatic beam coding: + Ripple: ≤ 10 % Air humidity: 15 % ... 95 %, non-condensing Connection type: Male connector M12, 5-pin Switching voltage LOW: 2 V DC Weight: 195 g PFHd: Cascaded systems: 1.3 1E-08 (EN ISO 13849) Type: Type 4 (IEC 61496) Typical range: 0 m ... 5 m Display elements: LEDs Synchronization: Optical, without separate synchronization Permitted cable length: ≤ 20 m