Specification: Part Number 1207178 Type: Type 4 (IEC 61496) Protection class: III (EN 61140) Configuration method: Hard wired Protective field height: 480 mm Permitted cable length: ≤ 20 m Housing material: Aluminum alloy ALMGSI 0.5 Ripple: ≤ 10 % Performance level: PL e (EN ISO 13849) Weight: 175 g Category: Category 4 (EN ISO 13849) Display elements: LEDs Typical range: 0 m ... 5 m Resolution: 24 mm Switching current: 300 mA Safe SICK device communication via EFI/SDL: - Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Shock resistance: 10 g, 16 ms (EN 60068-2-27) Ambient operating temperature: -20 °C ... +55 °C Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Synchronization: Optical, without separate synchronization Air humidity: 15 % ... 95 %, non-condensing Automatic beam coding: + Storage temperature: -25 °C ... +70 °C Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Beam coding: + Conductor cross-section: 0.34 mm² Restart interlock: + Power consumption: ≤ 3 A Connection type: Male connector M12, 5-pin Cascaded: - Response time: ≤ 13 ms Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Cable length: 350 mm Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Safe state in the event of a fault: At least one OSSD is in the OFF state. Scanning range: 0 m ... 4 m Enclosure rating: IP 65 (EN 60529) TM (mission time): 20 a (EN ISO 13849) Switching voltage LOW: 2 V DC External device monitoring (delivery status): Deactivated External device monitoring (EDM): + Restart interlock (delivery status): Deactivated PFHd: Standalone system: 4.3 1E-09 (EN ISO 13849) Housing cross-section (incl. system connection): 15 mm x 32 mm