Specification: Part Number 1207101 Beam coding: + Scanning range: 0 m ... 4 m Ambient operating temperature: -20 °C ... +55 °C TM (mission time): 20 a (EN ISO 13849) Switching current: 300 mA Protection class: III (EN 61140) Safe SICK device communication via EFI/SDL: - Configuration method: Hard wired Restart interlock: + Switching voltage LOW: 2 V DC Category: Category 4 (EN ISO 13849) Response time: ≤ 14 ms Protective field height: 420 mm Cable length: 350 mm Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) Typical range: 0 m ... 5 m External device monitoring (delivery status): Deactivated External device monitoring (EDM): + Safe state in the event of a fault: At least one OSSD is in the OFF state. Housing material: Aluminum alloy ALMGSI 0.5 Shock resistance: 10 g, 16 ms (EN 60068-2-27) Resolution: 14 mm Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Display elements: LEDs Conductor cross-section: 0.34 mm² Connection type: Male connector M12, 5-pin Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET PFHd: Standalone system: 4.3 1E-09 (EN ISO 13849) Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Cascaded: - Ripple: ≤ 10 % Permitted cable length: ≤ 20 m Automatic beam coding: + Air humidity: 15 % ... 95 %, non-condensing Power consumption: ≤ 3 A Housing cross-section (incl. system connection): 15 mm x 32 mm Weight: 155 g Enclosure rating: IP 65 (EN 60529) Synchronization: Optical, without separate synchronization Storage temperature: -25 °C ... +70 °C Performance level: PL e (EN ISO 13849) Type: Type 4 (IEC 61496) Restart interlock (delivery status): Deactivated