Specification: Part Number 1207227 Protection class: III (EN 61140) Scanning range: 0 m ... 4 m Protective field height: 360 mm Configuration method: Hard wired Automatic beam coding: + External device monitoring (EDM): + Restart interlock (delivery status): Deactivated Power consumption: ≤ 3 A Display elements: LEDs Cable length: 350 mm Safe state in the event of a fault: At least one OSSD is in the OFF state. Response time: ≤ 13 ms Cascaded: - Integration via Flexi Soft safety controller: CANopenDeviceNetEtherCATEtherNet/IPModbus TCPPROFIBUS DPPROFINET Category: Category 4 (EN ISO 13849) Storage temperature: -25 °C ... +70 °C Air humidity: 15 % ... 95 %, non-condensing Ripple: ≤ 10 % Safety integrity level: SIL3 (IEC 61508) SILCL3 (EN 62061) Enclosure rating: IP 65 (EN 60529) External device monitoring (delivery status): Deactivated Safe SICK device communication via EFI/SDL: - Type of output: PNP semiconductors, short-circuit protected, cross-circuit monitored Resolution: 24 mm Housing cross-section (incl. system connection): 15 mm x 32 mm Type: Type 4 (IEC 61496) Permitted cable length: ≤ 20 m Conductor cross-section: 0.34 mm² Synchronization: Optical, without separate synchronization Vibration resistance: 5 g, 10 Hz ... 55 Hz (EN 60068-2-6) Switching voltage LOW: 2 V DC Performance level: PL e (EN ISO 13849) Beam coding: + Connection type: Male connector M12, 5-pin TM (mission time): 20 a (EN ISO 13849) Switching current: 300 mA Shock resistance: 10 g, 16 ms (EN 60068-2-27) Supply voltage: 24 V DC (19.2 V DC ... 28.8 V DC) Ambient operating temperature: -20 °C ... +55 °C Typical range: 0 m ... 5 m Weight: 135 g Switching voltage HIGH: 24 V DC (VS - 2.25 V DC ... VS) PFHd: Standalone system: 4.3 1E-09 (EN ISO 13849) Housing material: Aluminum alloy ALMGSI 0.5 Restart interlock: +