Specification: Part Number 1054131 Actual length of cable extension: 3.2 m Resistance to shocks: 70 g, 6 ms (according to EN 60068-2-27) Relative humidity / Condensation: 90 % (condensation of the optical scanning not permitted) Working temperature range (encoder): -30 °C ... +70 °C, with AFM60B, 0 °C ... +70 °C, with AFM60E Resolution (wire draw + encoder): 0.03 mm Mass (measuring wire): 1.2 g/m MTTFd: mean time to dangerous failure: 250 a Working temperature range (combination): Wird definiert durch den höheren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik Connection type: Male connector M12, 8-pin, radial Initialization time: Ca. 50 ms SET (electronic adjustment): Via SET cable Clock frequency: 1 MHz 2 MHz Part number mechanic: 5322778 Encoder: Absolute encoders Number of steps per revolution: 8,192 Mounted encoder: AFM60 SSI Part number encoder: 1037863 Length of wire pulled out per revolution: 230 mm Spring return force: Ca. 5 N ... ca. 6.3 N Measuring wire diameter: 0.55 mm Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Mounted mechanic: MRA-G080-103D3 Enclosure rating mechanic: IP 50 Electrical interface: SSI Enclosure rating encoder: IP 67 Housing material, wire draw mechanism: Plastic, Noryl Mass (mechanics): 250 g Code type: Gray Wire acceleration: 10 m/s² Linearity: ≤ ± 2 mm Measuring range: 0 m ... 3 m Mass (including encoder): 510 g Measuring wire material: Highly flexible stranded steel 1.4401 stainless steel V4A Life of wire draw mechanism: 1 million cycles Hysteresis: ≤ 0.4 mm Working temperature range (mechanics): -30 °C ... +70 °C Repeatability: ≤ 0.2 mm Operating speed: 4 m/s EMC: (according to EN 61000-6-2 and EN 61000-6-3) Power consumption: 0.7 W Supply voltage: 4.5 V ... 32 V