Specification: Part Number 1054129 Measuring range: 0 m ... 3 m Hysteresis: ≤ 0.4 mm MTTFd: mean time to dangerous failure: 250 a Operating speed: 4 m/s Wire acceleration: 10 m/s² Mass (including encoder): 510 g Length of wire pulled out per revolution: 230 mm Encoder: Absolute encoders Mounted encoder: AFM60 SSI Enclosure rating mechanic: IP 50 Measuring wire material: Highly flexible stranded steel 1.4401 stainless steel V4A Actual length of cable extension: 3.2 m Initialization time: Ca. 50 ms Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Linearity: ≤ ± 2 mm Code type: Gray Repeatability: ≤ 0.2 mm Enclosure rating encoder: IP 67 Supply voltage: 4.5 V ... 32 V Spring return force: Ca. 5 N ... ca. 6.3 N Resolution (wire draw + encoder): 0.06 mm Part number encoder: 1037649 Electrical interface: SSI Mass (measuring wire): 1.2 g/m SET (electronic adjustment): Via SET cable Number of steps per revolution: 4,096 EMC: (according to EN 61000-6-2 and EN 61000-6-3) Relative humidity / Condensation: 90 % (condensation of the optical scanning not permitted) Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Clock frequency: 1 MHz 2 MHz Connection type: Male connector M12, 8-pin, radial Mounted mechanic: MRA-G080-103D3 Mass (mechanics): 250 g Measuring wire diameter: 0.55 mm Life of wire draw mechanism: 1 million cycles Housing material, wire draw mechanism: Plastic, Noryl Power consumption: 0.7 W Working temperature range (encoder): -30 °C ... +70 °C, with AFM60B, 0 °C ... +70 °C, with AFM60E Part number mechanic: 5322778 Working temperature range (combination): Wird definiert durch den höheren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik Working temperature range (mechanics): -30 °C ... +70 °C