Specification: Part Number 1031822 EMC: According to EN 61000-6-2 and EN 61000-6-3 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Initialization time: 80 ms Max. number of steps per revolution: 32,767 Measuring step deviation: 0.005 °, 0.016 ° Repeat accuracy: 0.005 ° Resolution power: 32,767 x 1 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Enclosure rating: IP 66, according to IEC 60529 Resistance to shocks: 50 g (according to EN 60068-2-27) Electrical interface: Cable, 22-pin, axial, 5 m Working temperature range: -20 °C ... 85 °C Max. number of revolutions: 1 Storage temperature range: -40 °C ... 100 °C Measuring step: 360 ° /number of lines Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) Operating voltage range: 10 V DC ... 32 V DC Operating power consumption (no load): 90 mA