ARS60-F4R04096

Specification: Part Number 1031604 Max. number of steps per revolution: 4,096 Storage temperature range: -40 °C ... 100 °C Operating power consumption (no load): 90 mA Resolution power: 4,096 x 1 Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Resistance to shocks: 50 g (according to EN 60068-2-27) Error limits: 0.035 ° (binary number of steps) 0.046 ° (non-binary number of steps) EMC: According to EN 61000-6-2 and EN 61000-6-3 Working temperature range: -20 °C ... 85 °C Measuring step: 360 ° /number of lines Electrical interface: Cable, 22-pin, axial, 1.5 m Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Enclosure rating: IP 66, according to IEC 60529 Max. number of revolutions: 1 Initialization time: 80 ms Measuring step deviation: 0.005 °, 0.016 ° Repeat accuracy: 0.005 ° Operating voltage range: 10 V DC ... 32 V DC
Part Number ARS60-F4R04096
Manufacture SICK