Specification: Part Number 1052324 Code sequence: CW/CCW, parameter adjustable Resistance to shocks: 50 g, 6 ms (according to EN 60068-2-27) Storage temperature range: -40 °C ... +100 °C, without package Shaft diameter: 12 mm Measuring step deviation: ± 0.2 ° Working temperature range: 0 °C ... +85 °C Permissible movement axial static/dynamic: ± 0.5 mm, ± 0.2 mm Max. angular acceleration: 500,000 rad/s² Max. number of steps per revolution: 4,096 Start up torque: 0.8 Ncm (+20 °C) Interface signals: Clock +, Clock -, Data +, Data- Error limits: ± 0.3 ° Electrical interface: SSI/Gray Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Permissible movement radial static/dynamic: ± 0.3 mm, ± 0.1 mm EMC: (according to EN 61000-6-2 and EN 61000-6-3) Bearing lifetime: 3.0 x 10^9 revolutions Power consumption: 0.5 W (without load) Measuring step: 0.09 ° 360 ° / number of steps SET (electronic adjustment): H-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Code type: Gray Connection type: Cable, 8-wire, universal, 5 m Resolution power: 4,096 x 4,096 Initialization time: 50 ms Mechanical interface: Through hollow shaft Moment of inertia of the rotor: 40 gcm² Operating torque: 0.6 Ncm (+20 °C) Clock frequency: 1 MHz MTTFd: mean time to dangerous failure: 250 a (EN ISO 13849-1) Max. number of revolutions: 4,096 Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Operating voltage range: 4.5 V DC ... 32 V DC Resolution: 12 bit x 12 bit CW/CCW (counting sequence when turning): L-active (L &;8801; 0 - 1,5 V, H &;8801; 2,0 - Us V) Reverse polarity protection: 1 Repeat accuracy: 0.002 ° Maximum operating speed: 9,000 /min Enclosure rating: IP 65 (according to IEC 60529), housing side, IP 65 (according to IEC 60529), shaft side