RC10-14-N3

General specifications Switching element function NAMUR, bistable Installation Output polarity NAMUR Inside diameter 10 mm Measuring cylinder Diameter 2.5 mm Length 3 mm Measuring cone Material 9S20K Nominal ratings Nominal voltage 8.2 V (R i approx. 1 kOm) Hysteresis typ. 1 % Reverse polarity protection reverse polarity protected Current consumption Traverse B 3 mA Traverse A 1 mA Functional safety related parameters MTTF d 2144 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Compliance with standards and directives Standard conformity NAMUR EN 60947-5-6:2000 IEC 60947-5-6:1999 Approvals and certificates FM approval Control drawing 116-0165F UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose Ambient conditions Ambient temperature -20 ... 100 °C (-4 ... 212 °F) Mechanical specifications Connection type cable PVC , 2 m Core cross-section 0.14 mm 2 Housing material PBT Degree of protection IP67 General information Use in the hazardous area see instruction manuals Category 2G