General specifications Switching element function PNP NO Rated operating distance 10 mm Installation flush (Requirements: see drawing below) Output polarity DC Assured operating distance 0 ... 8.1 mm Actuating element Ferrous and nonferrous targets Reduction factor r Al 0.4 Reduction factor r Cu 0.25 Reduction factor r 304 0.85 Reduction factor r St37 1 Nominal ratings Operating voltage 10 ... 30 V DC Switching frequency 0 ... 240 Hz Hysteresis 3 ... 15 typ. 10 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 2 V Operating current less than or equal to 200 mA Off-state current 10 mA No-load supply current less than or equal to 10 mA Operating voltage indicator LED, green Switching state indicator LED, yellow Functional safety related parameters MTTF d 880 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Approvals and certificates UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated less than or equal to 36 V Ambient conditions Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Mechanical specifications Connection type cable PUR , 2 m Core cross-section 0.5 mm 2 Housing material Stainless steel 1.4305 / AISI 303 Sensing face Stainless steel 1.4305 / AISI 303 Housing diameter 18 mm Degree of protection IP69K