NBB2-8GH40-E2-V3

General specifications Switching element function PNP NO Rated operating distance 2 mm Installation flush Output polarity DC Assured operating distance 0 ... 1.62 mm Reduction factor r Al 0.25 Reduction factor r Cu 0.2 Reduction factor r 304 0.63 Reduction factor r Brass 0.31 Nominal ratings Operating voltage 10 ... 30 V Switching frequency 0 ... 1500 Hz Hysteresis typ. 5 % Reverse polarity protection reverse polarity protected Short-circuit protection pulsing Voltage drop less than or equal to 3 V Operating current 0 ... 100 mA Off-state current 0 ... 0.5 mA typ. 10 mA at 25 °C No-load supply current less than or equal to 15 mA Switching state indicator Multihole-LED, yellow Functional safety related parameters MTTF d 2750 a Mission Time (T M ) 20 a Diagnostic Coverage (DC) 0 % Approvals and certificates UL approval cULus Listed, General Purpose CSA approval cCSAus Listed, General Purpose CCC approval CCC approval / marking not required for products rated less than or equal to 36 V Ambient conditions Ambient temperature -25 ... 70 °C (-13 ... 158 °F) Mechanical specifications Connection type M8 x 1 connector, 3-pin Housing material Stainless steel 1.4435 / AISI 316L Sensing face LCP, (conforms with FDA) Housing diameter 8 mm Degree of protection IP67 Mass 7 g