Reference signal Zero pulse, width 90° Output frequency ≤120 kHz ≤300 kHz (on request) POG 11 + ESL 93 output signals K1, K2, K0 + inverted Error output (only EMS) Phase shift 90° ±20° Admitted shaft load ≤300 N axial ≤450 N radial Scan ratio 40...60 % Flange EURO flange B10 Approval CE Consumption w/o load ≤5 mA Pulses per revolution 300...5000 Resistance IEC 60068-2-6 Vibration 10 g, 10-2000 Hz IEC 60068-2-27 Shock 100 g, 11 ms Protection DIN EN 60529 IP 67 Operating temperature -20...+85 °C Voltage supply 9...30 VDC; 5 VDC ±5 % Switching delay time ≤40 ms Emitted interference EN 61000-6-3 Operating speed ≤5000 rpm Consumption w/o load ≤100 mA Output stages HTL-P (power linedriver) TTL/RS422 Sensing method Optical Operating torque typ. 3 Ncm Switching hysteresis =30 % of switching speed Interference immunity EN 61000-6-2 manufacter SKU POG 11 + ESL 93 Voltage supply 12 VDC ±10 % Weight approx. 2.7 kg 2.9 kg (with option M) Shaft type ø11 mm solid shaft Size (flange) ø115 mm Connection 2x terminal box 3x terminal box (with option M) Current each output 40 mA (DC) Range of switching speed (ns) 3x 200...5000 rpm Materials Housing: aluminium die-cast Shaft: stainless steel Switching outputs 3 outputs, speed control Switching accuracy ±4 % (≤1500 rpm) ±2 % (>1500 rpm) Rotor moment of inertia 220 gcm²