Output stages HTL-P (power linedriver) TTL/RS422 Interference immunity EN 61000-6-2 Output frequency ≤120 kHz ≤300 kHz (on request) Sensing method Optical Resistance IEC 60068-2-6 Vibration 20 g, 10-2000 Hz IEC 60068-2-27 Shock 200 g, 6 ms Operating temperature -40...+100 °C -25...+100 °C (>3072 pulses per revolution) -50...+100 °C (optional) manufacter SKU POG 10 Protection DIN EN 60529 IP 66 Flange EURO flange B10 Materials Housing: aluminium die-cast Shaft: stainless steel Pulses per revolution 300...5000 Weight approx. 1.9 kg 2.1 kg (with option M) Phase shift 90° ±20° Size (flange) ø115 mm Rotor moment of inertia 200 gcm² POG 10 output signals K1, K2, K0 + inverted Error output (only EMS) Voltage supply 9...30 VDC 5 VDC ±5 % Explosion protection II 3 G Ex nA IIC T4 Gc (gas) II 3 D Ex tc IIIC T135°C Dc (dust) Operating torque typ. 2 Ncm Scan ratio 40...60 % Connection Terminal box 2x terminal box (with option M) Admitted shaft load ≤300 N axial ≤450 N radial Emitted interference EN 61000-6-3 Approvals CE UL approval / E256710 Shaft type ø11 mm solid shaft Reference signal Zero pulse, width 90° Consumption w/o load ≤100 mA Operating speed ≤12000 rpm (mechanical)