operating temperature -25 ... +85 °C short circuit protection yes current consumption max. (no load) 20 mA connection types cable PUR 3 x 0,25, 2 m MDRM 18U9524 dimension 18 mm reverse polarity protection yes, Vs to GND type cylindrical threaded protection class IP 67 housing material brass nickel plated axial misalignment max. 0,4 mm temperature drift ± 0,2 % (Full Scale) resolution 0,09 ° voltage supply range +Vs 12 ... 28 VDC material (sensing face) PBTP manufacter SKU MDRM 18U9524 angular range 160° linear system accuracy ± 0,25 % output signal 1 ... 9 VDC load resistance > 1000 Ohm working distance max. 5 mm, with magnet rotor MSFS output circuit voltage output response time < 4 ms