ITD 41 A 4 output signals A, B, N + inverted Sensing method Optical Mounting kit 050 Consumption w/o load ≤100 mA manufacter SKU ITD 41 A 4 Weight approx. 550 g Shaft type ø10...16 mm (blind hollow shaft) Interference immunity DIN EN 61000-6-2 Emitted interference DIN EN 61000-6-3 Output frequency ≤300 kHz (TTL) ≤160 kHz (HTL) Motor shaft tolerance 0.25 mm axial 0.1 mm radial Voltage supply 5 VDC ±5 % 8...30 VDC Materials Housing: aluminium, black, powder-coated Shaft: stainless steel Reference signal Zero pulse, width 90° Operating speed ≤8000 rpm ≤5000 rpm IP 65 (>70 °C) Output stages TTL linedriver (short-circuit proof) HTL push-pull (short-circuit proof) Connection Cable 1 m Size (flange) ø80 mm Operating temperature -20...+70 °C -20...+100 °C Pulses per revolution 2000...10000 Resistance DIN EN 60068-2-6 Vibration 10 g, 55-2000 Hz DIN EN 60068-2-27 Shock 30 g, 11 ms Relative humidity 90 % non-condensing Reverse polarity protection Yes Protection DIN EN 60529 IP 65 Starting torque ≤0.01 Nm (+20 °C)