voltage supply range +Vs 12 ... 36 VDC IR06.D03S-Q30.UA1Z.7SCV dimension 6,5 mm protection class IP 67 temperature drift ± 6 % (Full Scale; -10 ... +70 °C) ± 4 % (Full Scale; 0 ... +60 °C) operating temperature -10 ... +70 °C housing length 30 mm linearity error ± 300 µm (S = 0 ... 3 mm) ± 90 µm (S = 0,75 ... 2,25 mm) resolution < 0,001 mm (stat.) < 0,01 mm (dynam.) connection types cable, 2 m housing material stainless steel load resistance > 4000 Ohm manufacter SKU IR06.D03S-Q30.UA1Z.7SCV response time (factory characteristic) < 0,5 ms repeat accuracy < 0,02 mm type cylindrical smooth reverse polarity protection yes output signal 0 ... 10 VDC measuring distance Sd 0 ... 3 mm mounting type quasi-flush output circuit voltage output short circuit protection yes current consumption max. (no load) 10 mA