Explosion protection II 3 G Ex nA IIC T4 Gc (gas) II 3 D Ex tc IIIC T135°C Dc (dust) Admitted shaft load ≤30 N axial ≤40 N radial Weight approx. 450 g Reference signal Zero pulse, width 90° Operating temperature -30...+85 °C Resistance IEC 60068-2-6 Vibration 10 g, 10-2000 Hz IEC 60068-2-27 Shock 300 g, 6 ms Phase shift 90° ±8° Materials Housing: aluminium die-cast Shaft: stainless steel Sensing method Optical Pulses per revolution 200...10000 Output frequency ≤250 kHz Voltage supply 9...26 VDC 5 VDC ±5 % Approvals CE UL approval / E256710 Operating speed ≤12000 rpm (mechanical) Rotor moment of inertia 22 gcm² Shaft type ø8...12 mm (blind hollow shaft) Scan ratio 46...54 % Interference immunity EN 61000-6-2 Operating torque typ. 1 Ncm Connection Flange connector M23, 12-pin Mating connector Connecting cable (option) Output stages HTL TTL/RS422 Consumption w/o load ≤100 mA manufacter SKU HOG 60 Protection DIN EN 60529 IP 65 Size (flange) ø58 mm Emitted interference EN 61000-6-3 HOG 60 output signals A+, B+, R+, A-, B-, R-