protection class IP 54 output pulse length 10 ms type rectangular edge indicator LED yellow operating temperature 0 ... +50 °C optimum operating distance 40 mm measuring distance Sd 0 ... 55 mm light source pulsed red laser diode voltage supply range +Vs 10 ... 30 VDC front (optics) glass connector base (main connector) M12 x 1, 4 pin object speed < 2 m/sec object cycle distance > 13 mm laser class 2 measuring point visible red point power on indication LED green wave length 670 nm width / diameter 30 mm output circuit push-pull short circuit protection yes sync. input no counting rate < 280000 copies/h sensitivity single sheet/edge thickness 1,5 mm manufacter SKU FLDK 110G1010/S14 sensitivity adjustment no reverse polarity protection yes housing material PA 6 current consumption max. (no load) 180 mA