Protection DIN EN 60529 IP 65 (without shaft seal) IP 67 (with shaft seal) Voltage supply 10...30 VDC Shaft type ø6 x 10 mm, solid shaft with flat (synchro flange) Emitted interference DIN EN 61000-6-3 Steps per turn ≤4096 / 12 bit Programmable parameters Steps per revolution Number of revolutions Preset Scaling Rotating direction Resistance DIN EN 60068-2-6 Vibration 30 g, 10-2000 Hz DIN EN 60068-2-27 Shock 250 g, 6 ms Initializing time ≤250 ms after power on Relative humidity 95 % Interfaces CANopen® DeviceNet EtherCAT EtherNet/IP Profibus-DPV0/V2 PROFINET POWERLINK SAEJ1939 Size (flange) ø58 mm Materials Housing: steel zinc-coated Flange: aluminium Bus cover: zinc die-cast Solid shaft: stainless steel Admitted shaft load ≤40 N axial ≤80 N radial Flange Synchro flange Diagnostic functions Multiturn sensing Position error Sensing method Magnetic Interference immunity DIN EN 61000-6-2 Function Singleturn Device adress Rotary switch in bus cover (type-specific, see data sheet bus cover) Angular accuracy ±0.5 ° Status indicator DUO-LED integrated in bus cover Operating speed ≤6000 rpm Repeatability 0.3 ° Weight approx. 480 g Operating temperature -40...+85 °C (see general informations) Code Binary Consumption w/o load ≤200 mA (24 VDC) Code sequence CW default, programmable Connection Bus cover manufacter SKU BMSV 58S flexible - MAGRES Starting torque ≤2 Ncm (+20 °C, IP 65) ≤2.5 Ncm (+20 °C, IP 67) Approval UL approval / E217823