Specification: Part Number 1047607 Protocol (Ethernet): TCP/IP, OPC CAN bus: + Response time: ≥ 20 ms Object remission: 2 % ... > 1,000 % (reflectors) Integrated application: Field evaluation Detectable object shape: Almost any Function (Serial (RS-232)): Host, AUX Function (CAN bus): Outputs extension Heating: Yes Data transmission rate (Serial (RS-232)): 9.6 kBaud ... 115.2 kBaud Angular resolution: 0.25 ° 0.5 ° Amount of evaluated echoes: 2 Field of view: 270 ° Light source: Infrared (905 nm) Electrical connection: 1 x M12 circular plug-in connector Switching inputs: 2 Ethernet: + Scanning frequency: 25 Hz / 50 Hz Statistical error : ± 12 mm Function (Ethernet): Host DeviceNet: - Optical indicators: 1 7-segment display (plus 5 LEDs showing device status, contamination warning and initial condition) Ambient light safety: 40,000 lx Systematic error : ± 30 mm Switching outputs: 3 Weight: 1.1 kg, without connecting cables Field of application: Outdoor Shock resistance: EN 60068-2-27 (1993-03) Simultaneous processing cases: 10 Storage temperature: -30 °C ... +70 °C PROFINET: - Enclosure rating: IP 67 (EN 60529, Section 14.2.7) Serial (RS-232): + PROFIBUS DP: - Max. range with 10 % reflectivity: 18 m Protection class: III (EN 50178 (1997;10)) Dimensions: 105 mm x 102 mm x 162 mm Operating range: 0.5 m ... 50 m Fog correction: Yes Data transmission rate (Ethernet): 10/100 Mbit Vibration resistance: EN 60068-2-6 (1995-04) Number of field sets: 10 fields Laser class: 1 (IEC 60825-1 (2007-3)) Power consumption: 60 W Ambient operating temperature: -30 °C ... +50 °C Electromagnetic compatibility (EMC): EN 61000-6-2:2005 / EN 61000-6-4 (2007-01) Housing color: Gray (RAL 7032) Note on use: Not suitable for personnel protection Operating voltage: 10.8 V DC ... 30 V DC