Specification: Part Number 1041015 Power-up pulse protection: + Installation type: Non-flush Supply voltage: 10 V DC ... 30 V DC Cable material: PVC Housing: Short-body Thread length: 22 mm D: 45 mm Hysteresis: 5 % ... 15 % Note: The values are reference values which may vary E: 30 mm Assured sensing range Sa: 12.15 mm Switching frequency: 500 Hz Carbon steel St37 (Fe): 1 Brass (Br): Ca. 0.4 Temperature drift (of Sr): ± 10 % Remark: Associated graphic see "Installation" Design: Cylindrical Housing length: 51 mm Connection type: Cable, 3-wire, 2 m Housing material: Metal, Nickel-plated brass Output function: NO Voltage drop: ≤ 2 V Stainless steel (V2A, 304): Ca. 0.8 C: 30 mm A: 30 mm Short-circuit protection: + Reverse polarity protection: + Electrical wiring: DC 3-wire B: 60 mm Time delay before availability: ≤ 125 ms Ripple: ≤ 10 % Enclosure rating: IP 67 Power consumption: ≤ 10 mA Housing cap material: Plastic, PA6 Repeatability: ≤ 2 % Tightening torque, max.: 100 Nm Copper (Cu): Ca. 0.4 Aluminum (Al): Ca. 0.45 Output current Ia: ≤ 200 mA Switching output: PNP F: 120 mm Sensing range Sn: 15 mm EMC: According to EN 60947-5-2 Ambient operating temperature: -25 °C ... 75 °C Shock/vibration: 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm Thread size: M30 x 1.5