Specification: Part Number 1044127 Short-circuit protection: + Reverse polarity protection: + Thread size: M18 x 1 Sensing range Sn: 12 mm Time delay before availability: ≤ 100 ms Carbon steel St37 (Fe): 1 Note: The values are reference values which may vary Connection type: Connector M12, 4-pin Repeatability: ≤ 2 % Switching frequency: 1,000 Hz Supply voltage: 10 V DC ... 30 V DC Thread length: 42 mm Electrical wiring: DC 4-wire Output function: Complementary Remark: Associated graphic see "Installation" EMC: According to EN 60947-5-2 E: 24 mm Power consumption: ≤ 10 mA Assured sensing range Sa: 9.72 mm Installation type: Non-flush Brass (Br): Ca. 0.4 Housing length: 69 mm D: 36 mm Hysteresis: 5 % ... 15 % F: 96 mm Stainless steel (V2A, 304): Ca. 0.8 Housing material: Metal, Nickel-plated brass Voltage drop: ≤ 2 V A: 18 mm Ripple: ≤ 10 % Copper (Cu): Ca. 0.4 Enclosure rating: IP 67 Housing cap material: Plastic, PA6 Ambient operating temperature: -25 °C ... 75 °C Switching output: PNP Design: Cylindrical Output current Ia: ≤ 200 mA Aluminum (Al): Ca. 0.45 Temperature drift (of Sr): ± 10 % Shock/vibration: 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm Housing: Standard B: 36 mm C: 18 mm Power-up pulse protection: + Tightening torque, max.: ≤ 40 Nm