Specification: Part Number 1040786 Hysteresis: 5 % ... 15 % Remark: Associated graphic see "Installation" Output function: NC Design: Cylindrical A: 12 mm Electrical wiring: DC 3-wire Cable material: PVC Housing: Standard Switching output: PNP E: 16 mm B: 24 mm Sensing range Sn: 8 mm Enclosure rating: IP 67 Switching frequency: 2,000 Hz Stainless steel (V2A, 304): Ca. 0.8 Installation type: Non-flush Brass (Br): Ca. 0.4 Aluminum (Al): Ca. 0.45 Time delay before availability: ≤ 100 ms Output current Ia: ≤ 200 mA Supply voltage: 10 V DC ... 30 V DC Voltage drop: ≤ 2 V Power consumption: ≤ 10 mA Shock/vibration: 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm Ripple: ≤ 10 % Thread length: 43 mm Housing cap material: Plastic, PA6 Copper (Cu): Ca. 0.4 Assured sensing range Sa: 6.48 mm Housing length: 63 mm Connection type: Cable, 3-wire, 2 m F: 64 mm C: 12 mm Thread size: M12 x 1 Reverse polarity protection: + EMC: According to EN 60947-5-2 Housing material: Metal, Nickel-plated brass D: 24 mm Temperature drift (of Sr): ± 10 % Repeatability: ≤ 2 % Short-circuit protection: + Tightening torque, max.: 12 Nm Note: The values are reference values which may vary Ambient operating temperature: -25 °C ... 75 °C Power-up pulse protection: + Carbon steel St37 (Fe): 1