Specification: Part Number 1040762 Note: The values are reference values which may vary Short-circuit protection: + Thread size: M12 x 1 Supply voltage: 10 V DC ... 30 V DC Stainless steel (V2A, 304): Ca. 0.8 Housing: Standard D: 12 mm Shock/vibration: 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm Ripple: ≤ 10 % Sensing range Sn: 4 mm Design: Cylindrical E: 8 mm Temperature drift (of Sr): ± 10 % Output current Ia: ≤ 200 mA Installation type: Non-flush A: 12 mm Switching frequency: 2,000 Hz Switching output: NPN F: 32 mm Time delay before availability: ≤ 100 ms EMC: According to EN 60947-5-2 Power-up pulse protection: + Housing cap material: Plastic, PA6 Repeatability: ≤ 2 % Housing material: Metal, Nickel-plated brass Voltage drop: ≤ 2 V Assured sensing range Sa: 3.24 mm Tightening torque, max.: 12 Nm Ambient operating temperature: -25 °C ... 75 °C Reverse polarity protection: + Output function: NC Copper (Cu): Ca. 0.4 Remark: Associated graphic see "Installation" Aluminum (Al): Ca. 0.45 Power consumption: ≤ 10 mA Thread length: 43 mm Brass (Br): Ca. 0.4 C: 12 mm Housing length: 63 mm Electrical wiring: DC 3-wire Connection type: Cable, 3-wire, 2 m Carbon steel St37 (Fe): 1 B: 24 mm Hysteresis: 5 % ... 15 % Cable material: PVC Enclosure rating: IP 67