Specification: Part Number 1068254 Hysteresis: 5 % ... 15 % Power-up pulse: ≤ 5 ms Copper (Cu): Ca. 0.4 Repeatability: ≤ 2 % D: 12 mm Temperature drift (of Sr): ± 10 % Carbon steel St37 (Fe): 1 Housing length: 65 mm Load resistance, min.: 3 mA Note: The values are reference values which may vary Output function: NC Thread length: 48 mm Design: Cylindrical Supply voltage: 10 V DC ... 30 V DC Reverse polarity protection: + Off-state current: ≤ 0.8 mA Tightening torque, max.: Typ. 12 Nm Switching frequency: ± 2,000 Hz Shock/vibration: 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm EMC: According to EN 60947-5-2 Thread size: M12 x 1 Housing: Standard C: 12 mm Cable material: Oil-resistant PVC Short-circuit protection: + Stainless steel (V2A, 304): Ca. 0.8 Ripple: ≤ 10 % Power-up pulse protection: - Aluminum (Al): Ca. 0.45 B: 24 mm Brass (Br): Ca. 0.4 Sensing range Sn: 4 mm Installation type: Flush Electrical wiring: DC 2-wire Housing cap material: Plastic, PA6 Connection type: Cable, 2-wire, 2 m Remark: Associated graphic see "Installation" Power consumption: ≤ 10 mA Assured sensing range Sa: 3.24 mm Enclosure rating: IP 67 Ambient operating temperature: -25 °C ... +75 °C Output current Ia: ≤ 100 mA Housing material: Metal, Nickel-plated brass Time delay before availability: ≤ 100 ms Voltage drop: ≤ 4 V, ≤ 4.5 V F: 32 mm