Specification: Part Number 1040900 Shock/vibration: 30 g, 11 ms/10 Hz ... 55 Hz, 1 mm Output current Ia: ≤ 200 mA Reverse polarity protection: + Temperature drift (of Sr): ± 10 % Voltage drop: ≤ 2 V Repeatability: ≤ 2 % Installation type: Non-flush A: 8 mm Hysteresis: 5 % ... 15 % Ripple: ≤ 10 % Assured sensing range Sa: 3.24 mm Remark: Associated graphic see "Installation" Switching output: NPN Housing cap material: Plastic, PA6 Tightening torque, max.: Typ. 5 Nm Switching frequency: 4,000 Hz Time delay before availability: ≤ 100 ms Housing material: Metal, Nickel-plated brass Electrical wiring: DC 3-wire C: 8 mm Thread length: 30 mm Carbon steel St37 (Fe): 1 Sensing range Sn: 4 mm E: 8 mm F: 32 mm Stainless steel (V2A, 304): Ca. 0.8 Connection type: Cable, 3-wire, 2 m Supply voltage: 10 V DC ... 30 V DC Design: Cylindrical Power-up pulse protection: + D: 12 mm EMC: According to EN 60947-5-2 Short-circuit protection: + Enclosure rating: IP 67 Note: The values are reference values which may vary Housing: Standard B: 18 mm Brass (Br): Ca. 0.4 Output function: NC Housing length: 52 mm Aluminum (Al): Ca. 0.45 Copper (Cu): Ca. 0.4 Power consumption: ≤ 10 mA Cable material: PVC Ambient operating temperature: -25 °C ... 75 °C Thread size: M8 x 1