Specification: Part Number 1026518 Ripple : 5 Vpp Measuring range: 0.2 m ... 18 m, 6 % remission 0.2 m ... 30 m, 90 % remision Initialization time: 500 ms Ambient temperature: Storage: -25 ... +75 °C Operation with heating: -40 ... +50 °C Operation with cooling case: -40 ... +75 °C Output rate: 250 ms Temperature drift: Typ. 0.05 mm/K Repeatability : 1 mm Power consumption: Typ. 22 W Electromagnetic compatibility (EMC): EN 61000-6-2, EN 55011 / EN 60947-5-7: 2003-9 Supply voltage Vs: DC 10 V ... 30 V, reverse polarity protected, U s ≥ DC 24 V for devices with heating Resolution: ≤ 1 mm Data interface: RS-422 Weight: 1,000 g Protection class : II Enclosure rating: IP 65 Laser class: 2 (EN 60825/21 CFR 1.040) Mechanical load: Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 Typ. light spot size (distance): 10 mm (at 7 m) 100 mm (at 70 m) 45 mm (at 30 m) Multifunctional input (MF) : > 12 V Light source : Laser, red Data output: 20,000 CR LF in mm Connection type: Male connector, M12, 5-pin Accuracy : ± 3 mm