Specification: Part Number 1024082 Indication: Display Effect of air temperature: 1 ppm/K Output rate: 2 ms Multifunctional input (MF) : 1 x MF Mechanical load: Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 Effect of air pressure: 0.3 ppm/hPa Repeatability : 1 mm Ambient temperature: Operation: -10 ... 55 °C Operation with cooling case: -10 ... 75 °C Storage: -25 ... 75 °C Max. movement speed: 10 m/s Initialization time : 1.5 s Data interface: PROFIBUS DP Weight: Ca. 1,650 g Supply voltage Vs: DC 18 V ... 30 V, limit values Accuracy: ± 3 mm Ripple : < 5 Vpp Protection class : II Switching output : Push-pull: PNP/NPN (100 mA) Light source : Laser, red Laser class: 2 (EN 60825-1 / CDRH) Output current IA : ≤ 100 mA Measuring range : 0.15 m ... 150 m, on reflective tape "Diamond Grade" Resolution: 0.05 mm ... 5 mm Temperature drift: Typ. 0.1 mm/K Enclosure rating: IP 65 Electromagnetic compatibility (EMC): EN 61000-6-2, EN 55011 Connection type: Male connector, 2 x M12, 5-pin, B-coded, 1 x M16, 8-pin, B-coded Power consumption: At 24 V DC < 250 mA Typ. light spot size (distance): 130 mm (at 70 m) 270 mm (at 150 m) 360 mm (at 220 m)