Specification: Part Number 1041950 Supply voltage Vs: DC 18 V ... 30 V, limit values Effect of air pressure: 0.3 ppm/hPa Power consumption: At 24 V DC < 250 mA Protection class : II Max. movement speed: 10 m/s Initialization time : 1.5 s Measuring range: 0.15 m ... 220 m, on reflective tape "Diamond Grade" Weight: Ca. 1,650 g Ripple : < 5 Vpp Output rate: 2 ms Electromagnetic compatibility (EMC): EN 61000-6-2, EN 55011: Class B Switching output : Push-pull: PNP/NPN (100 mA) Light source : Laser, red Output current IA : ≤ 100 mA Resolution: 0.05 mm ... 5 mm Laser class: 2 (EN 60825-1 / CDRH) Indication: Display Ambient temperature: Operation: -10 ... 55 °C Operation with cooling case: -10 ... 75 °C Storage: -25 ... 75 °C Connection type: Male connector, 2 x M12, 5-pin, B-coded, 1 x M16, 8-pin, B-coded Effect of air temperature: 1 ppm/K Repeatability : 3 mm Temperature drift: Typ. 0.1 mm/K Typ. light spot size (distance): 130 mm (at 70 m) 270 mm (at 150 m) 360 mm (at 220 m) Enclosure rating: IP 65 Accuracy: ± 6 mm Multifunctional input (MF) : 1 x MF Mechanical load: Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 / -2-29 Sine: EN 600 68-2-6 Data interface: PROFIBUS DP