Specification: Part Number 1058165 Ambient temperature: Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C Connection type: Male connector, M12, SPEEDCON™ compatible Internal measurement cycle: 1 ms Output current IA : ≤ 100 mA Initialization time : Typ. 1.5 s Enclosure rating: IP 65 Power consumption: At 24 V DC < 1,000 mA Modulation frequency: Fix Resolution: 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm Temperature drift: Typ. 0.1 mm/K Output time: Synchronous to PLC request (dependent on interfaces) Protection class: III Switching output : B (push/pull) MF1, MF2 Weight : Ca. 800 g ... 1,600 g Supply voltage Vs: DC 18 V ... 30 V, limit values Ripple : 5 Vpp Measuring range: 0.15 m ... 100 m, On reflective tape "Diamond Grade" Max. movement speed: 30 m/s Repeatability : 0.5 mm Laser class: 2 (EN 60825-1 / CDRH) Light source : Laser, red Electromagnetic compatibility (EMC) : EN 61000-6-2 / EN 61000-6-4 Multifunctional input (MF) : 1 x MF1 Dead time: 2 ms Acceleration (max.): 15 m/s² Data interface: PROFINET Typ. light spot size (distance): 5 mm (+ 2 mm x distance in m) Accuracy : ± 2 mm Effect of air pressure: 0.3 ppm/hPa Mechanical load: Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 Indication: 6 digit 5 x 7 dot matrix display, LEDs Housing material: Aluminum/zinc die-cast Effect of air temperature: 1 ppm/K