Specification: Part Number 1059964 Modulation frequency: Fix Effect of air pressure: 0.3 ppm/hPa Laser class: 2 (EN 60825-1 / CDRH) Max. movement speed: 30 m/s Typ. light spot size (distance): 5 mm (+ 2 mm x distance in m) Temperature drift: Typ. 0.1 mm/K Multifunctional input (MF) : 1 x MF1 Connection type: Male connector, M12, SPEEDCON™ compatible Power consumption: At 24 V DC < 1,000 mA Supply voltage Vs: DC 18 V ... 30 V, limit values Repeatability : 2 mm (at dead time 10 ms), 1 mm (at dead time 30 ms) Weight : Ca. 800 g ... 1,600 g Effect of air temperature: 1 ppm/K Measuring range: 0.15 m ... 130 m, On reflective tape "Diamond Grade" Mechanical load: Noise: EN 600 68-2-64 Shock: EN 600 68-2-27 Sine: EN 600 68-2-6 Output time: Synchronous to PLC request (dependent on interfaces) Ripple : 5 Vpp Data interface: SSI Accuracy : ± 4 mm Internal measurement cycle: 1 ms Indication: 6 digit 5 x 7 dot matrix display, LEDs Electromagnetic compatibility (EMC) : EN 61000-6-2 / EN 61000-6-4 Enclosure rating: IP 65 Switching output : B (push/pull) MF1, MF2 Light source : Laser, red Housing material: Aluminum/zinc die-cast Ambient temperature : Operation with cooling case: -40 ... +75 °C Storage: -40 ... +75 °C Operation with heating: -40 ... +55 °C Protection class: III Initialization time : Typ. 1.5 s Output current IA : ≤ 100 mA Resolution: 0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm