Specification: Part Number 1037325 Reference signal, number: 1 Start up torque: 0.5 Ncm (+20 °C) Moment of inertia of the rotor: 6.2 gcm² Maximum output frequency: 300 kHz Storage temperature range: -40 °C ... +100 °C, without package Mass: 0.3 kg Resistance to shocks: 50 g (according to EN 60068-2-27) Permissible relative humidity: 90 % (condensation of the optical scanning not permitted) Enclosure rating: IP 65 (according to IEC 60529), shaft side, IP 67 (according to IEC 60529), housing side Working temperature range: 0 °C ... +85 °C Measuring step: 90 ° / electronically/number of lines MTTFd: mean time to dangerous failure: 300 a (EN ISO 13849-1) Shaft diameter: 10 mm x 19 mm Measuring step deviation: ± 0.2 ° Bearing lifetime: 3.6 x 10^10 revolutions Resistance to vibration: 20 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Reference signal, position: 90 °, electronically, gated with A and B Error limits: ± 0.3 ° Operating torque: 0.3 Ncm (+20 °C) Electrical interface: 10 V ... 32 V, HTL/Push pull, Cable, 8-pin, universal, 5 m Operating voltage range: 10 V ... 32 V Mechanical interface: Solid shaft, Face mount flange Power consumption: 0.5 W (without load) Load current max.: 30 mA Connection type: Cable, 8-wire, universal, 5 m Permissible shaft loading radial/axial: 40 N (axial), 80 N (radial) Max. angular acceleration: 500,000 rad/s² Pulses per revolution: 314 Maximum operating speed: 10,000 /min EMC: (according to EN 61000-6-2 and EN 61000-6-3) Initialization time: 40 ms