Specification: Part Number 1052618 Part number encoder: 1051018 Working temperature range (combination): Wird definiert durch den höheren mininalen und niedrigeren maximalen Wert des Arbeitstemperaturbereichs von Encoder und Mechanik Resistance to shocks: 80 g, 6 ms (according to EN 60068-2-27) Measuring range: 0 m ... 3 m Working temperature range (encoder): -10 °C ... +70 °C Actual length of cable extension: 3.2 m Working temperature range (mechanics): -30 °C ... +70 °C Resolution (wire draw + encoder): 0.03 mm Bus termination: Via DIP switches Measuring wire material: Highly flexible stranded steel 1.4401 stainless steel V4A Mounted encoder: A3M60 Number of steps per revolution: 8,192 Measuring wire diameter: 0.55 mm Linearity: ≤ ± 2 mm Encoder profile: Encoder profile version 1.1 class 1 and class 2 Mounted mechanic: MRA-G080-103D3 Electrical interface: PROFIBUS Wire acceleration: 10 m/s² Housing material, wire draw mechanism: Plastic, Noryl Operating speed: 4 m/s Life of wire draw mechanism: 1 million cycles Address setting: 0 ... 127, DIP switch Repeatability: ≤ 0.2 mm Relative humidity / Condensation: 95 % (condensation of the optical scanning not permitted) Connection type: Connector 3 x M12, 5-pin, axial MTTFd: mean time to dangerous failure: 60 a Enclosure rating encoder: IP 67 Encoder: Absolute encoders Mass (measuring wire): 1.2 g/m Resistance to vibration: 30 g, 10 Hz ... 2,000 Hz (according to EN 60068-2-6) Spring return force: Ca. 5 N ... ca. 6.3 N Mass (mechanics): 250 g SET (electronic adjustment): Via PRESET push button or protocol Length of wire pulled out per revolution: 230 mm EMC: (according to EN 61000-6-2 and EN 61000-6-3) Hysteresis: ≤ 0.4 mm Part number mechanic: 5322778 Mass (including encoder): 530 g Supply voltage: 10 V ... 32 V Protocol: PROFIBUS DP V0 Initialization time: Ca. 1 s Enclosure rating mechanic: IP 50 Power consumption: 1.5 W